Fusing - 21TR Plus
TM
The light bar should be installed with an external fuse or circuit breaker in the RED lead of the 2 conductor 10 AWG power cable of the
21TR Plus™ bar. The recommended external fuse size for the light bar is 30A. The internal circuitry of the Central Controller is reverse
polarity protected. Each output on the Central Controller board is protected against over current and over heating with automatically
resetting output devices.
Wiring - 21TR Plus
TM
Connect the black lead to a solid frame ground (earth), preferably the (-) or ground (earth) side of the battery, and the power wire to
the +12V terminal of the battery. Connect the remaining wires in the 16 conductor cable as shown in Table 3.
For the ArrowStik® function, connect the appropriate control wires to any control switch capable of providing +power at approximately
25ma current. As noted in the wire description, connecting both the LEFT Arrow and RIGHT Arrow wire to +power at the same time
enables the Center-Out ArrowStik function.
Table 3 - Control Wire Denitions - 21TR Plus
TM
Note: All control inputs are +power enabled.
Control Input Function Denition
Wire Color Function Description
GRN/BLK Level 1 Level 1 Emergency Mode
WHT/BLK Level 2 Level 2 Emergency Mode
RED/BLK Level 3 Level 3 Emergency Mode
ORG/BLK Take Down lights Take Down Lights Steady Burn (overrides Take Down Flash)
BLU/BLK Rear Cut-Off Blacks-Out Rear Facing LEDs
GRN/WHT Front Cut-Off Blacks-Out Front Facing LEDs
RED/WHT Right Alley Light Right Alley Steady Burn (overrides Alley Light Flash)
BLK/WHT Left Alley Light Left Alley Steady Burn (overrides Alley Light Flash)
WHT ArrowStik Flash ArrowStik Flash (overrides L1, L2 & L3 for rear of light bar)
BLK/RED** Pattern Select Pattern Select for ArrowStik, L1, L2 & L3, enables test mode)
BLK Take Down Flash Enables Take Down Lights Wig/Wag Flash
RED* ArrowStik Left Left ArrowStik (overrides L1, L2 & L3 for rear of light bar)
GRN Cruise Lights End LEDs only (overridden by all other functions except for Dim)
ORG* ArrowStik Right Right ArrowStik (overrides L1, L2 & L3 for rear of light bar)
BLU Light bar DIM Sets LED to Dim mode
BLU/WHT Alley Light Flash Enables Alley Light Wig/Wag Flash
Flash Pattern Selection - 21TR Plus
TM
The Pattern Select wire is the BLK/RED wire in the 16 conductor control cable and is activated by momentarily touching the wire to
+12V. Reference Table 4 for ash patterns.
Step 1
Power-up the light bar by connecting the Red wire to +12V and the Black wire to ground, and select Level 1 on a user-purchased 3
Level controller or, if the Lightbar is not yet connected to a controller, energize Level-1 by connecting the GRN/BLK wire in the 16
conductor control cable to +12V.
Step 2
Observe the ashing pattern operation and determine which pattern is in operation for Level-1. Refer to Table 1. This table shows the
available ash patterns. Note: the Factory Default is different and identied in the table for each of the ash mode Levels (L1, L2, L3).
Once the ash pattern has been determined, proceed to Step 3.
This Product contains high intensity LED devices. To prevent eye damage, DO NOT
stare into light beam at close range.
WARNING!
!