Code-3 RX 2700CC Manual do Utilizador Página 5

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 4
LED DIRECTIONAL MODULES
In addition to the 360° warning modules the lightbar may be equipped with a number of single head front-rear warning LED modules. These modules
are available in either the, PriZm 8-LED Reector, PriZm 3-LED Reector, 3-LED OLP OPTIX (dual stack 3-LED lightheads).
Operating Specications for front-rear module:
Operating Voltage: 10-16 VDC, Reverse Polarity Protection
Current Draw : Standby 16ma
Flashing Module:
Red/Amber - .25A avg @ 12.8 Volts
Blue/White - .4A avg @ 12.8 Volts
Steady Burn Module:
Red/Amber - .5A avg @ 12.8 Volts
Blue/White - .8A avg @ 12.8 Volts
Available Colors: Red , Blue, Amber, and White
The ash pattern for these modules is chosen by the following procedure:
Selecting Flash Patterns
The Pattern Select wire is the BLK/RED wire in the sixteen conductor lightbar control cable and is activated by momentarily touching the wire to
+power.
STEP 1
Power-up the lightbar and select the Level-1 ash mode by applying +power to the GRN/BLK wire in the 16 conductor control cable.
STEP 2
Observe the ashing pattern operation and determine which pattern is in operation for Level-1. Refer to Table 1A. This table shows the available
ash patterns. Note: the Factory Default is different and identied in the table for each of the ash mode Levels (L1, L2, L3). Once the ash pattern
has been determined, proceed to Step 3.
STEP 3
Scroll to the next ash pattern by momentarily holding the Pattern Select wire (BLK/RED) to +power for ~1 sec, until the lightbar LEDs switches ash
patterns, and then releasing it. This will step to the next pattern in numbered order as listed in Table 1A for the selected 3-Level mode. The new
pattern is automatically stored each time. Repeat this procedure for Level-2 and Level-3.
Note: HOLD the Pattern Select wire to the +POWER source for about 1 second and release then observe that the ash pattern has
changed to the next pattern in the sequence. To restore the Factory Default Emergency Warning Flash Patterns, hold the Pattern Select
wire on the +POWER source for ~four (4) seconds while L1, L2 or L3 is enabled.
Note: All control inputs are +power enabled.
Control Input Function Denitions
Wire Color Function Description
GRN/BLK Level 1 Level 1 Emergency Mode
WHT/BLK Level 2 Level 2 Emergency Mode
RED/BLK Level 3 Level 3 Emergency Mode
ORG/BLK Takedown lights Takedown Lights Steady Burn (overrides Takedown Flash)
BLU/BLK Rear Cut-Off Blacks-Out Rear Facing LEDs
GRN/WHT Front Cut-Off Blacks-Out Front Facing LEDs
RED/WHT Right Alley Light Right Alley Steady Burn (overrides Alley Light Flash)
BLK/WHT Left Alley Light Left Alley Steady Burn (overrides Alley Light Flash)
WHT ArrowStik Flash ArrowStik Flash (overrides L1, L2 & L3 for rear of light bar)
BLK/RED** Pattern Select Pattern Select for ArrowStik, L1, L2 & L3, enables test mode)
BLK Takedown Flash Enables Takedown Lights Wig/Wag Flash
RED* ArrowStik Left Left ArrowStik (overrides L1, L2 & L3 for rear of light bar)
GRN Cruise Lights End LEDs only (overridden by all other functions)
ORG* ArrowStik Right Right ArrowStik (overrides L1, L2 & L3 for rear of light bar)
BLU Light bar DIM Sets LED to Dim mode
BLU/WHT Alley Light Flash Enables Alley Light Wig/Wag Flash